|
Display Method
.. TFT Color LCD DISPLAY
.. WAVE DISPLAY : Scrolling Method
.. MONITOR SIZE : 6.4 inches
.. RESOLUTION : 320 x 240 PIXELS
.. DISPLAY SPEED : 12.5, 25, 50mm/sec for ECG, SpOv(2)
.. WAVEFORM DISPLAY TIME : 2.5 sec
.. WAVEFORM FREEZE : ECG, SpOv(2)Waveform Freeze for a time
.. WAVEFORM DISPLAY : ECG, SpOv(2)
.. WAVEFORM NUMBER : 3 TRACE WAVEFORM
.. VALUE DISPLAY : HeartRate, SpOv(2)Saturation, NiBP Pressure
NiBP(Non-invasive
Blood Pressure Measurement)
.. MEASUREMENT METHOD : Oscillometric Method, Auto Measurement
.. VALUE DISPLAY : Systolic, Diastolic, Mean Pressure
.. MEASUREMENT RANGES
PRESSURE VALUE ADULT/CHILE MODE NEONATE MODE
SYSTOLIC 50~240MMHG 40~130MMHG
MEAN 20~200MMHG 35~120MMHG
DIASTOLIC 15~180MMHG 20~100MMHG
.. ACCURACY : 8 mmHg
.. CUFF INFLATION TIME : 3 ~20 Seconds (250mmHg)
.. Digital Manometer Mode Usage
.. ALARM RANGE
.. High : 5.270 mmHg
.. Low : 0.265 mmHg
.. Activation of measurement : Manual, continuous for five
minute,
automatic : 2, 5, 10, 30, 60, 120 minutes interval
TREND
.. PARAMETERS : Heart Rate, SpOv(2)Saturation, Pulse Rate,
NiBP Pressure
.. TABULAR TREND : 1/ 10/ 24/ 24 Hour(Resolution 1/10/30/60
minute)
.. GRAPHICAL TREND : 3/ 6/ 12/ 24 Hour(Resolution 1/2/4/8
minute)
ALARM
.. ALARM APPLICATION : ALL PARAMETERS
.. ALARM DISPLAY : Sound
PRINTER
.. METHOD : Thermal dot array
.. CHANNEL : 1ch / 2ch
.. SPEED : 12.5mm/sec, 25mm/sec
.. TREND : Tabular format
.. EVENT : Auto/Manual, Auto On/Off
.. PAPER WIDTH : 57mm
MONITOR
PHYSICAL SPECIFICATIONS
.. SIZE : 290W×225H×170D(mm)
.. WEIGHT : 5.8 Kg(with Battery and Module)
.. POWER REQUIREMENTS : 100~240VAC,50/60Hz, about 48W
.. POWER FAIL PROTECTION
.. BATTERY : 12V 2.0A (Sealed Rechargeable)
|
ECG
Measurement
.. ECG LEAD : 3-Lead/5-Lead( I, II, III, aVR, aVL, aVF,
V, Cal )
.. FREQUENCY FILTER : High Frequency Remove Filter, 50/60Hz
Notch Remove Filter
.. INPUT IMPEDANCE : Greater than 5Mohm(in 50/60Hz)
.. INPUT CIRCUIT CURRENT : Less than 50 ?A
.. BASELINE RECOVER TIME : Less than 5 seconds after defibrillation
.. FREQUENCY BANDWIDTH : 0.5Hz ~ 35Hz
.. GAIN : 5, 10, 20 mm/mV
.. CALIBRATION WAVEFORM : 1mv . 1Hz Waveform
.. INPUT RANGE : Max ± 5mV
.. DC OFFSET : -300mV to +300mV
HR(Heart
Rate)
.. Range : 30 to 300 bpm
.. Accuracy : ± 2% in whole detectable range
.. Resolution : 1bpm
.. Adjustment : 5 bpm steps
SpO2(
Pulse Oximetry)
.. RANGE : 21 ~ 99% SpO2
.. ACCURACY :
.. 70 . 100% SpO2 : ± 2digits
.. 50 . 69% SpO2 : ± 3digits
.. 20 . 49% SpO2 : Unspecified
.. ALARM RANGE
.. Low limit : 21 . 98% SpO2
.. High limit : 22 . 99% SpO2
.. PULSE RANGE : 30 ~ 250bpm
.. PULSE MEASUREMENT ACCURACY : ±3bm
STANDARD
ACCESSORIES
.. 3-Leads Type ECG Cable 1EA
.. NiBP Cuff for Adults 1EA
.. Gray Hose for NiBP Cuff 1EA
.. Disposable Electrodes (3pcs/set) 1 SET
.. SpOv(2)Finger Proble(reusable) 1EA
.. Power Cord 1EA
.. Operation Manual 1EA
OPTIONAL
ACCESSORIES
.. 5-Leads Type ECG Cable
.. NiBP Cuff for Children
.. Connection Cable for Measuring Module
.. Cart
ENVIRONMENTAL
SPECIFICATIONS
.. TEMPERATURE
.. Operating : 10 to 40 ? ( 45 . 113 ?)
.. Storage : -10 to 50 ? ( 14 . 122 ?)
.. RELATIVE HUMIDITY
.. Operating : 95% RH max. @ 40 ?( 113 ?) (without condensation)
.. Storage : 10 . 95% RH max. @ 50 ?( 122 ?)
.. ATMOSPHERIC PRESSURE
.. Operating : 70 . 106KPa
|